RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

SCF14-50JFN
1/4" CELLFLEX® Superflexible Foam-Dielectric Coaxial Cable

Rev : N | Rev date : 15 Jan 2024

CELLFLEX® 1/4" superflexible cable support CBRS, C-Band and LAA up to 6GHz; flame retardant/ halogen free jacket

FEATURES / BENEFITS

  • Low Attenuation
    The low attenuation of CELLFLEX® coaxial cable results in highly efficient signal transferin your RF system.
  • Complete Shielding
    The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Low VSWR
    Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
    CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • High Power Rating
    Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
    materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
  • Wide Range of Application
    Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
  • Meets or Exceeds: IEC 60754-1, -2; IEC 60332-1-1, -2;IEC 61034-1, -2; IEC 60332-3-24 (formerly IEC 60332-3-C)


1/4" CELLFLEX® Superflexible Foam Dielectric Coaxial Cable

Technical features

Applications

ApplicationsIndoorWireless CommunicationHF DefenseMicrowaveMobile RadioCable Solutions

Structure

Cable TypeFoam-Dielectric, Superflexible
Size1/4
Jacket OptionBlack
Inner Conductor Diameter mm (in)1.9 (0.075)
Inner Conductor MaterialCopper-Clad Aluminum Wire
Dielectric Diameter mm (in)4.3 (0.17)
Dielectric MaterialFoam Polyethylene
Outer Conductor Diameter mm (in)6.5 (0.26)
Outer Conductor MaterialCorrugated Copper
Jacket Diameter mm (in)7.8 (0.31)
Jacket MaterialPolyethylene, PE, Metalhydroxite Filling

Testing and Environmental

Fire PerformanceFlame Retardant, LS0H
Flame Retardant Jacket SpecificationsMeets/Exceeds: IEC 60754-1, -2; IEC 60332-1, -3.C; UL 1581; UL 1666; NEC type CATVR; EN45545-2(GER production)
Installation Temperature °C(°F)-25 to 60 (-13 to 140)
Storage Temperature °C (°F)-70 to 85 (-94 to 185)
Operation Temperature °C(°F)-50 to 85 (-58 to 185)

Electrical Specifications

Impedance Ω50 +/- 1
Maximum Frequency GHz20.4
Velocity %81
Capacitance pF/m (pF/ft)82 (25)
Inductance uH/m (uH/ft)0.207 (0.063)
Peak Power Rating kW5.5
RF Peak Voltage Volts740
Jacket Spark Volt RMS5000
Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft)10.5 (3.19)
Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft)9 (2.74)
Return Loss (VSWR) Performance20 (1.22) @ 450-617 MHz
24 (1.13) @ 617-960 MHz
24 (1.13) @ 1695-2200 MHz
20 (1.22) @ 2300-2700 MHz
18 (1.28) @ 3500-4200 MHz
16 (1.37) @ 5150-6000 MHz
Phase Stabilized

Phase stabilized and phase matched cables and assemblies are available upon request.

Temperature & PowerStandard

Mechanical Specifications

Cable Weight, Nominal kg/m (lb/ft)0.07 (0.05)
Minimum Bending Radius, Repeated Bendsmm (in)25 (1)
Bending Moment Nm (lb-ft)0.7 (0.5)
Tensile Strength N (lb)600 (135)
Recommended / Maximum Clamp Spacing m (ft)0.2 / 0.2 (0.67 / 0.67)

Attenuation @ 20°C (68°F) and Power Rating @ 40°C (104°F)

Frequency, MHzdB per 100mdB per 100ftPower, kW
0.5 0.40 0.12 5.50
1 0.57 0.17 5.50
1.5 0.70 0.21 5.50
2 0.80 0.25 5.50
10 1.81 0.55 3.66
20 2.56 0.78 2.58
30 3.15 0.96 2.10
50 4.08 1.24 1.62
88 5.45 1.66 1.21
100 5.82 1.77 1.14
108 6.06 1.85 1.09
150 7.17 2.19 0.92
174 7.75 2.36 0.85
200 8.33 2.54 0.79
300 10.30 3.13 0.64
400 12 3.65 0.55
450 12.70 3.88 0.52
500 13.50 4.10 0.49
512 13.60 4.15 0.49
600 14.80 4.52 0.45
700 16.10 4.91 0.41
800 17.30 5.27 0.38
824 17.60 5.35 0.38
894 18.40 5.59 0.36
900 18.40 5.61 0.36
925 18.70 5.70 0.35
960 19.10 5.81 0.35
1000 19.50 5.94 0.34
1250 22 6.71 0.30
1500 24.30 7.41 0.27
1700 26.10 7.94 0.25
1800 26.90 8.20 0.25
2000 28.50 8.69 0.23
2100 29.30 8.93 0.23
2200 30.10 9.20 0.22
2400 31.60 9.60 0.21
3000 35.80 10.90 0.19
3500 39.10 11.90 0.17
4000 42.20 12.90 0.16
5000 48 14.60 0.14
6000 53.40 16.30 0.12
7000 58.60 17.80 0.11
8000 63.40 19.30 0.10
9000 68.10 20.80 0.10
10000 72.60 22.10 0.09
12000 81 24.80 0.08
14000 89 27.20 0.07
16000 97 29.60 0.07
18000 105 31.90 0.06
20000 112 34.20 0.06
20400 113 34.60 0.06

External Document Links

Notes

Phase stabilized versions available upon request.

Phase stabilized versions available upon request.