FONF-MM06S-XXXM
HYBRIFLEX® Fiber Optic Cable Assembly, MTP12/APC Male to MTP12/APC Male, LSZH, Indoor

Rev : B | Rev date : 03 Mar 2022
HYBRIFLEX fiber only cable assemby, 12 single mode fibers, pre-terminated with an MTP12 male connector on both ends of this LSZH, indoor cable. Optimized for Radio over Fiber (RoF) applications, for use within the RFS "Plug and Play" RoF solution. This product is designed to connect two spans of backbone cable which have been terminated with MTP female connectors.

FEATURES / BENEFITS

  • High precision MTP/APC fiber connector provides low insertion loss, high return loss,excellent stability and durability
  • Available in a range of standard or customized lengths to simplify network design
  • MTP connectors are terminated and fully tested in controlled conditions to ensure optimum performance and reliability
  • RFS' "Plug and Play" solution simplifies network design, minimizes installation/testing time and the necessary on site skills

 


Technical features

Structure

Cable Type12 single mode fibers (G657A2), LSZH jacket, yellow
Number of Fiber12

Mechanical Specifications

Outer Diameter Nominal mm (in)4.5 (0.177)
Minimum Bending Radius, (Operating)mm (in)30 (1.181)
Minimum Bending Radius, (Installation)mm (in)50 (1.969)
Tensile Strength (Operating)130 N
Tensile Strength (Installation)440 N
Crush Resistance (Operating)300 N / 10 cm
Crush Resistance (Installation)1000 N / 10 cm

Cable Jacket

Jacket MaterialLSZH

F/O Cable Specifications

F/O Cable TypeLoose-tube, Single Mode
Core/Clad µm9 /125
F/O Cable JacketLSZH
F/O Standards (Meets or Exceeds)G657A2
Fiber Termination End 1MTP/APC male, single mode, yellow housing, IEC 61754-7
Fiber Termination End 2MTP/APC male, single mode, yellow housing, IEC 61754-7
Fiber Attenuation≤ 0.36dB/km λ=1310nm ; ≤0.22dB/km λ =1550nm
Connector Insertion LossMTP:Max. 0.35 dB @ 1310&1550nm/ IEC 61300-3-4 Method B
Connector Return LossMTP: Min. 60 dB @ 1310&1550nm

Testing and Environmental

Storage Temperature °C (°F)-25 to 70 (-13 to 158 )
Operation Temperature °C (°F)-20 to 60 (-4 to 140 )
Installation Temperature °C (°F)-10 to 55 (14 to 131 )

Ordering Information

<30 m 1 PC in a bag

Additional Assemblies

LengthModel Name
1 mFONF-MM06S-001M
2 mFONF-MM06S-002M
3 mFONF-MM06S-003M
4 mFONF-MM06S-004M
5 mFONF-MM06S-005M
6 mFONF-MM06S-006M
7 mFONF-MM06S-007M
8 mFONF-MM06S-008M
9 mFONF-MM06S-009M
10 mFONF-MM06S-010M

External Document Links