HB014-S-01U1-S1J
RFS Technologies Hybrid Cable Standard, Cabling Solution for 1 RRU
Rev : E | Rev date : 07 Mar 2023
A hybrid cable designed to transmit both electrical power and optical signals in a single cable. Two electrical power conductors and two fibre optic sub units, each containing one bend insensitive singlemode fiber are surrounded by fillers. Incorporation of water blocking tapes and a UV stable jacket ensure long term operation in outdoor applications. The inclusion of fillers ensures the fully circular construction can be efficiently installed in conventional trays or ducting systems
FEATURES / BENEFITS
- Circular construction prevents snagging during installation
- Bend insensitive optical fiber simplifies installation and termination
- Singlemode fiber provides the ultimate future proof support for high bandwidth services
- Sutiable for outdoor applications
Structure |
|---|
| Cable Type | | Hybrid (2 x 1.5mm² DC wires & 2 x 1.6mm butterfly SM fibres, 0.4mm steel wire strength members in bow-type formation) | | Fire Performance | | The outer sheath adopts a low-smoke, flame retardant compound to meet IEC60332-1, halogen-free, meeting CPR classification: Eca to BS EN 13501-6:2014 | | Number of Fiber | | 2 |
|
Mechanical Specifications |
|---|
| Outer Diameter Nominal | mm (in) | 9 (0.354) | | Cable Weight | kg/m (lb/ft) | 0.108 (0.073) | | Minimum Bending Radius, (Operating) | mm (in) | 90 (3.543) | | Minimum Bending Radius, (Installation) | mm (in) | 180 (7.087) | | Recommended / Maximum Clamp Spacing | m (ft) | 0.8 / 1 (2.75 / 3.3) | | Tensile Strength (Operating) | | 300 (N) IEC 60794-1-2-E | | Tensile Strength (Installation) | | 600 (N) IEC 60794-1-2-E | | Crush Resistance (Operating) | | 300 N /100 mm complaint to IEC 60794-1-2-E3 | | Crush Resistance (Installation) | | 1,000 N /100 mm complaint to IEC 60794-1-2-E3 |
|
DC Power Cable Specifications |
|---|
| Number of DC Pairs | | 1 | | Maximum DC-Resistance Power Cable | Ω/km (Ω/kft) | 13.3 (4.05) | | Cross Section of Power Cable | mm² (AWG) | 1.5 (15) | | DC Wire Information | | 30 x 0.26 Pure Annealed Copper (Class 5) | | DC Wire Jacket Thickness | mm (in) | 0.7 (0.028) | | DC Cable Diameter | mm (in) | 3.1 (0.12) | | DC Cable Jacket | | UV stable red and blue XLPE standard compliance IEC60228 |
|
Cable Jacket |
|---|
| Jacket Material | | UV stable black LSZH |
|
F/O Cable Specifications |
|---|
| F/O Cable Type | | Tight buffer (2xsimplex bow-type formation 2.0mmx1.6mm and acrylate secondary protection) | | Number of F/O Pairs | | 1 | | Core/Clad | µm | 9 /125 | | F/O Cable Jacket | | Colour coded Yellow + Blue LSZH sheath length marked per meter | | F/O Standards (Meets or Exceeds) | | ITU G 657.A2 | | Fiber Attenuation | | < 0.4 dB/km @ 1310nm, < 0.3 dB/km @1550nm |
|
Testing and Environmental |
|---|
| Storage Temperature | °C (°F) | -20 to 50 (-4 to 122 ) | | Operation Temperature | °C (°F) | -20 to 80 (-4 to 180 ) | | Installation Temperature | °C (°F) | -10 to 50 (14 to 122 ) |
|