7/8" RCF RADIAFLEX Cable, Halogen Free, Flame/Fire Retardant, Low Smoke, Aluminum Outer Conductor

Rev : P1 | Rev date : 11 May 2026
  • RADIAFLEX® functions as a distributed antenna to provide communications in tunnels, mines and large building complexes and is the solution for any application in confined areas.
  • Slots in the aluminum outer conductor allow a controlled portion of the internal RF energy to be radiated into the surrounding environment. Conversely, a signal transmitted near the cable will couple into the slots and be carried along the cable length.
  • RADIAFLEX® is used for both one-way and two-way communication systems and because of its broadband capability, a single radiating cable can handle multiple communication systems simultaneously.
  • This RADIAFLEX® radiating cable utilize a low-loss cellular polyethylene foam dielectric and a corrugated copper or aluminum outer conductor which offers a combination of remarkable flexibility, high strength and excellent electrical performance.

FEATURES / BENEFITS

  • Broadband radiating cable supporting all wireless application between 30 MHz to 3800 MHz
  • Ideally suited for application that require low bending radius
  • Robust radiating cable operational under all enviromental conditions as e.g. harsh tunnels or mines


Technical features

General Specifications

Size7/8

Electrical Specifications

Max. Operating Frequency MHz3800
Cable TypeRCF
ImpedanceOhm50 +/- 2
Velocity, percent%88
Capacitance pF/m (pF/ft)75 (22.9)
DC-resistance inner conductor, ohm/km (ohm/1000ft)Ω/km (Ω/1000ft)2.3 (0.7)
DC-resistance outer conductor, ohm/km (ohm/1000ft)Ω/km (Ω/1000ft)1.9 (0.58)
Stop bands MHzNone
Frequency Selection MHz600, 900, 1800/1900, 2200, 2400, 2500, 2700

Mechanical Specifications

JacketFlame Retardant
Jacket ColorStandard Black, other colors on request
Jacket DescriptionHalogen free, non corrosive, flame retardant, low smoke
Slot DesignMilled (Two-Row)
Inner Conductor MaterialCopper Tube
Outer Conductor MaterialAnnularly Corrugated Aluminum
Diameter Inner Conductor mm (in)9.4 (0.37)
Diameter Outer Conductor mm (in)25.2 (0.99)
Diameter over Jacket Nominal mm (in)28 (1.1)
Minimum Bending Radius, Single Bend mm (in)250 (10)
Cable Weight kg/m (lb/ft)0.42 (0.29)
Tensile ForceN (lb)1400 (315)
Recommended / Maximum Clamp Spacing m (ft)0.9 (3)
Minimum Distance to Wall mm (in)50 (2)

Testing and Environmental

Jacket Testing MethodsTest methods for fire behaviour of cable :
IEC 60754-1/-2 smoke emission, halogen free, non corrosive
IEC 61034 low smoke
IEC 60332-1 flame retardant

Temperature Specifications

Storage Temperature °C(°F)-10 to 50 (14 to 122 )
Installation Temperature °C(°F)-25 to 60 (-13 to 140 )
Operation Temperature °C(°F)-40 to 85 (-40 to 185 )

Attenuation

Frequency, MHzLongitudinal Loss, dB/100 m (dB/100 ft)Coupling Loss 50%, dBCoupling Loss 95%, dB
75 1.23 (0.37) 60 69.8
150 1.85 (0.56) 71.3 80.5
450 3.52 (1.07) 60.2 69.9
800 4.87 (1.48) 76.7 88.3
870 5.09 (1.55) 73.2 84.6
900 4.71 (1.44) 72.7 83.9
960 5.38 (1.64) 72.1 83.2
1800 7.79 (2.37) 77.1 88.8
1900 8.04 (2.45) 74.2 86.1
2000 78.31 (2.53) 72.7 84.8
2200 8.85 (2.7) 70.5 83.3
2400 9.44 (2.88) 70.3 83
2600 10.03 (3.06) 69.8 81.9
2700 10.28 (3.13) 69 80.8
3200 11.84 (3.61) 64 78.8
3300 12.57 (3.83) 65.5 79.2
3400 12.51 (3.81) 67.6 81.1
3500 11.62 (3.54) 67.6 80.5
3600 12.07 (3.68) 66.1 79.8
3700 12.21 (3.72) 66.4 79.7
3800 12.15 (3.7) 66.7 79.8

External Document Links

Notes

  • Coupling loss as well as longitudinal attenuation of RADIAFLEX® cables are measured by the free space method according to IEC 61196-4.
  • Coupling loss values are average values of all three spatial orientations (radial, parallel and orthogonal) of dipole antenna.
  • Coupling loss values are given with a tolerance of +10 dB and longitudinal loss values with a tolerance of +5%. Note: Measured values below nominal are better. They are not limited by any tolerance-range.
  • As with any radiating cable, the performance in building or tunnel environments may deviate from figures based on free space method.