RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+
Please upgrade your browser to continue
Products
Contents
Products
Cables & Waveguides
Combiners & Splitters
Product Cross Reference
Technical Support
Plenum Cable
1/2" Copper Clearfill
1/2" Aluminum Clearfill
7/8" Air Dielectric Plenum
1 5/8" Air Dielectric Plenum
Field Installable Connectors
Tools & Accessories
RF Factory Fit Jumper
1/4"
3/8"
1/2"
CELLFLEX RF Feeder Cable
1/4"
3/8"
1/2"
7/8"
1-1/4"
1-5/8"
Field Installable Connectors
Tools & Accessories
DragonSkin Systems
DragonSkin 1/2'' Cable
2 Hour Cabinet
Field Installable Connectors
Tools & Accessories
Indoor Passive Components
Visit our Dragonskin Cable website
RADIAFLEX Radiating Cables
1/2"
7/8"
1-1/4"
1-5/8"
RADIAFLEX Connectors & Accessories
Field Installable Connectors
Installation Accessories
RADIAFLEX Radiating Waveguide
HYBRIFLEX Optical Fiber & Power Cables
Hybrid
Optical Fiber
Power
Accessories
Air Dielectric Cable [HCA] High Power RF Air Cable
New HCA Cables
7/8"
1-1/8"
1-5/8"
2-1/4"
3"
4"
5"
5-1/2"
6-1/8"
Field Installable Connectors
Tools & Accessories
Cable Pressurization
Dehydrators
Microwave Waveguides
Elliptical Waveguides
Rectangular Waveguides
Twistflex Waveguides
Waveguide Tools & Accessories
Site Kits
Indoor RF Components
Power Splitter
Directional Coupler
Hybrid Combiner
Tapper
Termination Load
DC Block
Product Cross-Reference
Solutions
Indoor Solutions
Macro Site Solutions
Fiber, Power and Hybrid Connectivity
Product Cross Reference
Services
RADIAFLEX Radiating Cables
1/2"
7/8"
1-1/4"
1-5/8"
RADIAFLEX Connectors & Accessories
Field Installable Connectors
Installation Accessories
RADIAFLEX Radiating Waveguide
Plenum Cable
1/2" Copper Clearfill
1/2" Aluminum Clearfill
7/8" Air Dielectric Plenum
1 5/8" Air Dielectric Plenum
Field Installable Connectors
Tools & Accessories
DragonSkin Systems
DragonSkin 1/2" Cable
2 Hour Cabinet
Field Installable Connectors
Tools & Accessories
Indoor Passive Components
CELLFLEX RF Feeder Cable
1/4"
3/8"
1/2"
7/8"
1-1/4"
1-5/8"
Field Installable Connectors
Tools & Accessories
Air Dielectric Cable [HCA] High Power RF Cable
New HCA Cables
7/8"
1-1/8"
1-5/8"
2-1/4"
Field Installable Connectors
Tools & Accessories
RF Factory Fit Jumper
1/4"
3/8"
1/2"
Indoor RF Components
Power Splitter
Directional Coupler
Hybrid Combiner
Tapper
Termination Load
DC Block
Indoor Antennas
Outdoor/Indoor RF Components
Multiplexers
HYBRIFLEX Optical Fiber & Power Cables
Optical Fiber
Accessories
CELLFLEX RF Feeder Cable
1/4"
3/8"
1/2"
7/8"
1-1/4"
1-5/8"
Field Installable Connectors
Tools & Accessories
Air Dielectric Cable [HCA] High Power RF Cable
7/8"
1-1/8"
1-5/8"
2-1/4"
Field Installable Connectors
Tools & Accessories
HYBRIFLEX Optical Fiber & Power Cables
Hybrid
Optical Fiber
Power
Accessories
RF Factory Fit Jumper
1/4"
3/8"
1/2"
Outdoor/Indoor RF Components
Multiplexers
Microwave Waveguides
Elliptical Waveguides
Rectangular Waveguides
Microwave Tools & Accessories
Clamps, Hangers
Connectors
Grounding kits
Hoisting
Pressurization
Tools
Twistflex
Wall Feed Through
Site Kits
For BSA inquiries please click here to visit the Amphenol-Antennas website
HYBRIFLEX Optical Fiber & Power Cables
Hybrid
Optical Fiber
Accessories
Product Cross Reference
Distributors
News
Press Releases
Events
Company
About us
History
Responsibility
Sister Companies
Resources
Brochures & Leaflets
Technical support
Product Cross Reference List
Join Our Team
RFS Technologies Routing Guide 2024
Contact Us
Contact Information
Information Request Form
Sister Companies
My e-catalog
Home
/
Indoor Solutions
/
RF Factory Fit Jumper
/
1/2"
/
Jumper ICA12 indoor/plenum-rated
RF Factory Fit Jumper - 1/2" - Jumper ICA12 indoor/plenum-rated
Filters
Cable Type
1/2" Low Loss, Air Dielectric
(8)
Jumper Type
Factory-Fit (Premium)
(8)
Connector A
N Male
(8)
Connector B
N Male
(8)
Jacket
Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
(8)
8 results found
Compare
Default
Sort By A-Z
Sort By Z-A
NMNMI12P-400FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 40 ft
Compare
Quick view
Close quick view
NMNMI12P-400FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 40 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 26.4, 1.1, 1395, 1432, 26.4, 1.1, 1700, 2155, 24, 1.13, 2300, 2500, 18, 1.29, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-030FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 3 ft
Compare
Quick view
Close quick view
NMNMI12P-030FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 3 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 30, 1.065, 1395, 1432, 30, 1.065, 1700, 2155, 26.4, 1.1, 2300, 2500, 20, 1.22, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-060FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 6 ft
Compare
Quick view
Close quick view
NMNMI12P-060FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 6 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 30, 1.065, 1395, 1432, 30, 1.065, 1700, 2155, 26.4, 1.1, 2300, 2500, 20, 1.22, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-090FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 9 ft
Compare
Quick view
Close quick view
NMNMI12P-090FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 9 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 30, 1.065, 1395, 1432, 30, 1.065, 1700, 2155, 26.4, 1.1, 2300, 2500, 20, 1.22, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-100FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 10 ft
Compare
Quick view
Close quick view
NMNMI12P-100FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 10 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 30, 1.065, 1395, 1432, 30, 1.065, 1700, 2155, 26.4, 1.1, 2300, 2500, 20, 1.22, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-120FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 12 ft
Compare
Quick view
Close quick view
NMNMI12P-120FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 12 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 30, 1.065, 1395, 1432, 30, 1.065, 1700, 2155, 26.4, 1.1, 2300, 2500, 20, 1.22, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-150FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 15 ft
Compare
Quick view
Close quick view
NMNMI12P-150FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 15 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 30, 1.065, 1395, 1432, 26.4, 1.1, 1700, 2155, 26.4, 1.1, 2300, 2500, 18, 1.29, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare
NMNMI12P-200FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 20 ft
Compare
Quick view
Close quick view
NMNMI12P-200FFP
ClearFill®Line Factory-Fit Jumper Assembly for In-Building Application,
NM/NM, 1/2" ClearFill®Line Plenum-Rated Air Dielectric, 20 ft
Jacket
: Blue PVC
Flame retardant, plenum-rated, CMP-ETL listed to UL444
Canadian CSA C.22.2/FT6
VSWR, Return Loss,VSWR (dB)
: 30, 1.065, 460, 806, 30, 1.065, 806, 960, 28, 1.08, 1395, 1432, 26.4, 1.1, 1700, 2155, 26.4, 1.1, 2300, 2500, 18, 1.29, 4400, 5900
Close quick view
Add to my e-catalog
Download PDF datasheet
View related documents
See related products
Compare