RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

HCA400-50JPLB
4" Air-Dielectric Coaxial Cable, 50 ohm, Plenum Rated, Black Jacket

Rev : C | Rev date : 11 Mar 2024

4" low loss air dielectric cable, plenum rated, UV resistant black PVC Jacket, applicable to both outdoor and indoor applications.

RFS Technologies' air dielectric cables are air filled coaxial cables which consist of an inner conductor and an outer conductor. A dielectric helix is used to center the inner conductor to the outer conductor. Air dielectric cables have low attenuation and high power rating which make them perfect choice of high RF power transmission lines, such as in FM, TV and radar systems and networks. Air cables also have better flexibility and crush resistance than other solutions such as rigid lines.

FEATURES / BENEFITS

  • Low Attenuation
    The low attenuation of this coaxial cable results in highly efficient signal transfer in your RF system.
  • Complete Shielding
    The solid outer conductor of this coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Low VSWR
    Standard and low VSWR versions of this coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
    Coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also guaranteed by the state-of-the-art manufacturing process at the factory.
  • High Power Rating
    Low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials enable this cable to provide long operating life at high transmit power levels.
  • Wide Range of Application
    Air cables are good choices for telecom, broadcasting, radar and HF defense applications.
  • Plenum Rated
    PVC jacket prevents fire from spreading, enables JPLB cables to meet and exceed all applicable plenum standards of flame travel and smoke.
  • Reinforced Jacket to Sustain Outdoor Applications
    Spcial additives in the jacketing compound improve the outdoor durability of the PVC jacket by minimizing the surface degradation caused by sunlight and other UV sources.


4" Air Dielectric Coaxial Cable

Technical features

Applications

ApplicationsTV & RadioHF DefenseCable Solutions

Structure

Cable TypeAir-Dielectric, Corrugated
Size4
Jacket OptionBlack
Inner Conductor Diameter mm (in)34.8 (1.37)
Inner Conductor MaterialCorrugated Copper Tube
Dielectric Diameter mm (in)75.3 (2.96)
Dielectric MaterialHelical Polyethylene Spacer
Outer Conductor Diameter mm (in)85.5 (3.36)
Outer Conductor MaterialCorrugated Copper
Jacket Diameter mm (in)90.5 (3.56)
Jacket MaterialUVR PVC (UltraViolet Resistant PolyVinylChloride)

Testing and Environmental

Fire PerformanceFlame Retardant, Plenum Rated
Flame Retardant Jacket SpecificationsMeet/Exceeds Steiner Tunnel Test Method UL 910, NEC 820-53 (a) CATVP, NFPA-262
Installation Temperature °C(°F)-25 to 60 (-13 to 140)
Storage Temperature °C (°F)-60 to 85 (-76 to 185)
Operation Temperature °C(°F)-40 to 85 (-40 to 185)

Electrical Specifications

Impedance Ω50 +/- 0.5
Maximum Frequency GHz1.66
Velocity %96
Capacitance pF/m (pF/ft)70 (21.3)
Inductance uH/m (uH/ft)0.175 (0.053)
Peak Power Rating kW940
RF Peak Voltage Volts9700
Jacket Spark Volt RMS8000
Inner Conductor dc Resistance Ω/1000 m (Ω/1000 ft)0.43 (0.13)
Outer Conductor dc Resistance Ω/1000 m (Ω/1000 ft)0.13 (0.04)
Return Loss (VSWR) PerformanceTypical 20.8dB (1.2 VSWR) or better within the operation bands of most global frequency ranges. Premium also available. Contact factory for options in your specific frequency band.
Phase Stabilized

Phase stabilizing, phase matching, and connector assembly services are available upon request.

Temperature & PowerStandard

Mechanical Specifications

Cable Weight, Nominal kg/m (lb/ft)3.12 (2.1)
Minimum Bending Radius, Single Bendmm (in)380 (15)
Minimum Bending Radius, Repeated Bendsmm (in)890 (35)
Bending Moment Nm (lb-ft)215 (159)
Tensile Strength N (lb)1800 (405)
Recommended / Maximum Clamp Spacing m (ft)0.8 / 1.2 (2.75 / 4)

Attenuation @ 20°C (68°F) and Power Rating @ 40°C (104°F)

Frequency, MHzdB per 100mdB per 100ftPower, kW
0.5 0.03 0.01 792
1 0.04 0.01 561
1.5 0.04 0.01 457
2 0.05 0.02 395
10 0.11 0.03 175
20 0.16 0.05 123
30 0.19 0.06 100
50 0.25 0.08 77.40
88 0.34 0.10 57.90
100 0.36 0.11 54.10
108 0.38 0.12 52
150 0.45 0.14 44
174 0.48 0.15 40.80
200 0.52 0.16 38
300 0.65 0.20 30.90
400 0.76 0.23 26.70
450 0.81 0.25 25.10
500 0.86 0.26 23.80
512 0.87 0.26 23.60
600 0.95 0.29 21.80
700 1.03 0.31 20.20
800 1.11 0.34 18.90
824 1.13 0.34 18.60
894 1.18 0.36 18
900 1.19 0.36 17.80
925 1.21 0.37 17.60
960 1.23 0.38 17.30
1000 1.26 0.38 17

Related Products

Product Type Model Number (click to access datasheet)
EIA Connector (O ring sealing version) 318EIA-HCA400-019
EIA Connector Kit (connector + coupling element) 318EIA-HCA400-019KT
EIA Connector Re-installation Kit 318EIA-HCA400-019RK
Cable Hanger Options CLAMP-400 (Butterfly)
Angle Member Adaptor ANGLE-CLPI (for butterfly hangers)
Grounding Kit GKFORM60-400
Hoisting Grip HOIST1-300L
Wall Feed Through Kit WF-400
Weather Proofing Kit WPFG-1
Dehydrator and Accessories BD Series

Note: More related products or options may be availabe but not listed here.

External Document Links