RFS Technologies website is optimized for recent browsers :
IE9+, Chrome 31+, Firefox 31+, Opera 28+, Safari 7+


My e-catalog

HB158-U12S24-100LI
HYBRIFLEX® Hybrid Feeder Cabling Solution 12x24, 1-5/8”, 12 pairs 6AWG, Low-Inductance Coaxial Power Wire, 24 pairs Single-Mode Fiber, DLC Connectors, 100 ft

Rev : G | Rev date : 20 May 2022

RFS’ HYBRIFLEX Remote Radio Head (RRH) hybrid feeder cabling solution combines optical fiber and DC power for RRHs in a single lightweight aluminum corrugated cable, making it the world’s most innovative solution for RRH deployments. It was developed to reduce installation complexity and costs at Cellular sites.

HYBRIFLEX allows mobile operators deploying an RRH architecture to standardize the RRH installation process. HYBRIFLEX combines optical fiber (multi-mode or single-mode) and power in a single corrugated cable. It may eliminate the need for junction boxes as well as works in conjuction with and can connect multiple RRHs with a single feeder. Standard RFS CELLFLEX® accessories can be used with HYBRIFLEX cable. Both pre-connectorized and on-site options are available.

FEATURES / BENEFITS

  • Aluminum corrugated armor with outstanding bending characteristics – Minimizes installation time and enables mechanical protection and shielding
  • Same accessories as 1-5/8" coaxial cable
  • Outer conductor grounding – Utilizes same grounding methods as coaxial cable
  • Lightweight solution and compact design – Decreases tower loading
  • Robust cabling – Eliminates need for expensive cable trays and ducts
  • Installation of tight bundled fiber optic cable pairs directly to the RRH – Reduces CAPEX and wind load by eliminating need for interconnection
  • Optical fiber and power cables housed in single corrugated cable – Saves CAPEX by standardizing RRH cable installation and reducing installation requirements
  • UL-Listed, flame-retardant jacket, UV protected assembles - Allows both indoor and outdoor applications
  • Maximum robustnessFully armored cable includes riser trunk and top outdoor breakout

TECHNICAL FEATURES

Structure 

Cable Type   HYBRIFLEX® Low Inductance
Fire Performance   Flame Retardant
Size   1-5/8"
Lengthm (ft)30.4 (100)

Mechanical Specifications 

Outer Diameter Nominal mm (in) 50.19 (1.976)
Cable Weight kg/m (lb/ft) 4.76 (3.2)
Minimum Bending Radius, Single Bend mm (in) 254 (10)
Minimum Bending Radius, Multiple Bends mm (in) 508 (20)
Recommended / Maximum Clamp Spacing m (ft) 1 / 1.2 (3.25 / 4)

Armor Specifications

Armor Type   Corrugated Aluminum
Maximum DC-Resistance of Armor Ω/km (Ω/kft) 0.58 (0.178)
Diameter Corrugated Armor mm (in) 46.4 (1.83)

Cable Jacket 

UV-Protection Individual and External Jacket   Yes

DC Power Cable Specifications

Number of DC Pairs   12
Maximum DC-Resistance Power Cable Ω/km (Ω/kft) 1.4 (0.41)
Cross Section of Power Cable mm² (AWG) 13.3 (6)
DC Wire Jacket Material   PVC
DC Cable Single Bending Radius mm (in) 137 (5.4)
DC Cable Diameter mm (in) 9.3 (0.365)
DC Cable Jacket Material   PVC
DC Standards (Meets or Exceeds)   For use in UL 2882, PVC, RoHS/REACH Compliant
Break-out Length (Top) mm (in) 812 (32)
Break-out Length (Bottom) mm (in) 812 (32)
Alarm Wire   8 (4 twisted pairs), 0.8 mm2 (8), 18 AWG
Alarm Wire Standards (Meets or Exceeds)   UL Standard 1063, 1581 VW-1, MTW Oil and Gasoline RES1 SUNRES (Cable meets UL requirements), RoHS/REACH Compliant

F/O Cable Specifications

F/O Cable Type   G657-A1 Single Mode, Bend Tolerant
Number of F/O Pairs   24
Core/Clad µm 9/125
Secondary Protection Nominal µm (in) 900 (0.035)
Single Bending Radius mm (in) 157 (6.2)
Cable Diameter   5.512 (0.217)
F/O Standards (Meets or Exceeds)   UL Listed Type OFNR (UL1666), RoHS Compliant
Optical Loss dB/Km 0.5 @ 1310 nm
0.5 @ 1550 nm
Fiber Termination End 1   DLC connector
Fiber Termination End 2   DLC connector
FO Break-out Length (Top) mm (in) 1524 (60)
FO Break-out Length (Bottom) mm (in) 1524 (60)

Testing and Environmental

Storage Temperature °C (°F) -40 to 70 (-40 to 158)
Operation Temperature °C (°F) -40 to 65 (-40 to 149)
Installation Temperature °C (°F) -20 to 65 (-4 to 149)
Jacket Specifications   UL2882, UL Listed

Additional Assembly Lengths 

Model Number Length (ft)
HB158-U12S24-10-LI 10
HB158-U12S24-20-LI 20
HB158-U12S24-30-LI 30
HB158-U12S24-40-LI 40
HB158-U12S24-50-LI 50
HB158-U12S24-60-LI 60
HB158-U12S24-70-LI 70
HB158-U12S24-80-LI 80
HB158-U12S24-90-LI 90
HB158-U12S24-100LI 100
HB158-U12S24-110LI 110
HB158-U12S24-120LI 120
HB158-U12S24-130LI 130
HB158-U12S24-140LI 140
HB158-U12S24-150LI 150
HB158-U12S24-160LI 160
HB158-U12S24-170LI 170
HB158-U12S24-180LI 180
HB158-U12S24-190LI 190
HB158-U12S24-200LI 200
HB158-U12S24-210LI 210
HB158-U12S24-220LI 220
HB158-U12S24-230LI 230
HB158-U12S24-240LI 240
HB158-U12S24-250LI 250
HB158-U12S24-260LI 260
HB158-U12S24-270LI 270
HB158-U12S24-280LI 280
HB158-U12S24-290LI 290
HB158-U12S24-300LI 300
HB158-U12S24-310LI 310
HB158-U12S24-320LI 320
HB158-U12S24-330LI 330
HB158-U12S24-340LI 340
HB158-U12S24-350LI 350

 

EXTERNAL DOCUMENT LINKS

Installation Guidelines: Download

QuickShip 2.0 Program Information:  Download

On-line Factory Test Results: View

Additional Assembly Lengths 

Model Number Length (ft)
HB158-U12S24-360LI 360
HB158-U12S24-370LI 370
HB158-U12S24-380LI 380
HB158-U12S24-390LI 390
HB158-U12S24-400LI 400
HB158-U12S24-410LI 410
HB158-U12S24-420LI 420
HB158-U12S24-430LI 430
HB158-U12S24-440LI 440
HB158-U12S24-450LI 450
HB158-U12S24-460LI 460
HB158-U12S24-470LI 470
HB158-U12S24-480LI 480
HB158-U12S24-490LI 490
HB158-U12S24-500LI 500
HB158-U12S24-510LI 510
HB158-U12S24-520LI 520
HB158-U12S24-530LI 530
HB158-U12S24-540LI 540
HB158-U12S24-550LI 550
HB158-U12S24-560LI 560
HB158-U12S24-570LI 570
HB158-U12S24-580LI 580
HB158-U12S24-590LI 590
HB158-U12S24-600LI 600
HB158-U12S24-610LI 610
HB158-U12S24-620LI 620
HB158-U12S24-640LI 640
HB158-U12S24-700LI 700
HB158-U12S24-720LI 720

NOTES

Nominal length equals length of trunk not including top and bottom breakouts; breakout lengths add additionally to the total assembly length tip to tip.

Includes 4 pairs of wires used to carry alarm signals.

The package also includes a kit of special RFS-designed DC insulating boots, 1 per coaxial power wire, used to properly protect and insulate the DC wires after stripping the jacket, avoiding possible short-circuits while wiring it to the distribution boxes.

 

DC INSULATING BOOT

PRE-PACKED HYBRIFLEX KITS FOR EASY INTEGRATION INTO RAYCAP JUNCTION BOXES

RFS now offers Kitting options for most hybrid risers and jumpers that include both the cable assembly and the Raycap inserts. For reference, kits have a “K” as the third digit in the model number. HB158 does not require an additional gland/insert for proper installation and sealing into the Distribution Boxes.

Kit Model Prefix Assembly Prefix Assembly Qty Raycap Insert Kit Insert Kit Contents Raycap Insert Kit Qty
HBK114 HB114 1 RFS-TRUNK-KIT (2) 190‐0620, Insert, M75, 1H, 40mm 1
HBK058 HBF058 RFS-JUMP-KIT (1) 190‐0621, Insert, M75, 3H, 22mm, Split w/ plugs
HBK012 HBF012 RFS-JUMP-KIT-2 (1) 190‐0903, Insert, M75, 2H, 15mm, Split w/ plugs
FRK-N FR-N RFS-FIBER-KIT (1) 190‐0657, Insert, M75, 6H, 6.1mm, Split w/ plugs